Pipeline AC Interference and Mitigation

Share on facebook
Share on linkedin
When pipelines share land with power transmission lines, cathodic protection alone won’t protect against destructive corrosion. Learn about mitigation strategies to reduce the effects of AC interference.

Scene #1:

Pipeline AC Interference & Mitigation.

Scene #2:

Steel pipelines and power transmission lines are often installed near each other in narrow corridors.

This minimizes the impact on the communities around them and makes efficient use of the land. 

Using common land makes it easier to install, operate and maintain utilities. But, it can also lead to damage and hazardous situations due to AC interference.

Scene #3:

AC current from transmission lines interferes with nearby pipelines through the following mechanisms:

  • Inductive Coupling
  • Resistive (or Conductive) Coupling
  • Capacitive Coupling

Scene #4:

Inductive Coupling occurs because AC current induces a voltage in adjacent conductors.
Thus, normal operation of transmission lines creates voltage gradients in pipelines installed nearby.

The induced voltages in the pipeline cause corrosive processes to occur faster.

Induced voltages also create a hazard for service technicians who need to maintain and repair the pipelines.

Scene #5:

Resistive coupling only occurs during fault conditions. For example, damage from a lightning strike may direct current through the grounding structure.

The increase in ground current causes the electrical potential of the soil to rise. Since the pipeline is in direct contact with the soil, its electrical potential also rises.

While this is not a common occurrence, it can add to the AC induced voltage in the pipeline, thus increasing the corrosion and hazard potential.

Scene #6:

Capacitive coupling only occurs when the pipeline is not touching the ground. Thus, capacitive coupling happens on pipelines installed above-ground, or on pipelines resting on skids before installation.

When the pipeline is above-ground, it is electrically-isolated. So, there is a voltage difference between the AC power lines and the pipeline.

The voltage difference increases the risk of arcing. Arcing is a hazard for nearby vehicles, for example, where the fuel might ignite.

Scene #7:

There are several mitigation strategies that can reduce the effects of AC interference. Increasing distance between transmission lines and the pipeline decreases the magnitude of interference.

Where space is limited, providing paths for current to escape along the pipeline ensures that voltage does not build up in the pipeline.

Many components are available to manage the current in a pipeline system, and therefore mitigate AC interference. Some of these are DC decouplers, surge protectors, grounding cells and galvanic anode installation cathodic protection systems.

Scene #8:

Computer modeling programs are a key component of AC interference mitigation strategy. With modeling programs, we can visualize problems and solutions along the entire system.

Used by trained engineers, these mitigation strategies are effective in protecting pipelines from AC corrosion caused by nearby power lines.

Scene #9:

Got a complicated pipeline project that requires sharing land with power transmission lines? 

Allied Corrosion Industries, Inc. has worked on many long-distance pipelines, requiring both cathodic protection and AC interference mitigation strategies to ensure long life of these assets. Inquire today about design for your project.

Leave a Reply

About Allied Corrosion

Allied Corrosion Industries, Inc. is a full service corrosion control corporation providing design, installation and maintenance of corrosion solutions and cathodic protection systems since 1980. We are also a materials and test equipment provider, offering a full line of corrosion-related products.

Recent Blogs

Follow Us

Stay Informed!

Get new posts delivered straight to your inbox.
The information you provide is voluntary and is used to send you the requested information and for marketing purposes.
Close Menu
×

Cart